Uniview CAB-LC3100B-E2-IN Cable Management Junction Box
6,067.00 EGP
Pick up from the Woodmart Store
To pick up today
Free
Courier delivery
Our courier will deliver to the specified address
2-3 Days
Free
DHL Courier delivery
DHL courier will deliver to the specified address
1-3 Days
Free
Warranty 1 year
Free 30-Day returns
Payment Methods:
Description
Uniview CAB-LC3100B-E2-IN Cable Management Junction Box
Uniview CAB-LC3100B-E2-IN Cat6 UTP Network Cable 305m
The Cat6 Cable Uniview CAB-LC3100B-E2-IN is a professional network cable designed for structured cabling, surveillance systems, business networks, office installations, and other Ethernet applications. It comes in a 305-meter roll and uses solid bare copper conductors to provide dependable signal transmission for modern network infrastructure.
With its Category 6 UTP construction, 24AWG conductors, durable PVC outer sheath, and orange finish, this cable is suitable for installers who need a practical and reliable solution for long network runs inside offices, commercial buildings, surveillance environments, and enterprise projects.
Cat6 Cable for Professional Network Installations
The Uniview CAB-LC3100B-E2-IN is built according to Category 6 network cabling requirements and is designed to support stable Ethernet communication across structured network environments.
Category 6 cabling is widely used in office networks, CCTV systems, access control installations, IP phone deployments, data networks, and other structured cabling projects where reliable communication between devices is important.
The UTP design uses four twisted pairs to help reduce interference and maintain consistent signal quality during transmission.
305 Meter Packing Length
The cable is supplied in a 305 ±1 meter length, making it suitable for large installations where multiple network runs are required.
A 305-meter roll provides installers with enough cable for offices, buildings, server rooms, surveillance projects, and commercial environments without requiring frequent replacement of smaller cable boxes.
This length is particularly convenient for professional installers working on projects that include multiple network outlets, access points, IP cameras, switches, and communication devices.
Solid Bare Copper Conductors
One of the most important features of the CAB-LC3100B-E2-IN is its use of solid bare copper conductors. Uniview specifies 24AWG copper conductors with a nominal conductor diameter of approximately 0.50 mm.
Solid copper conductors provide stable electrical performance and are commonly preferred for permanent structured cabling installations.
The specified DC resistance is less than or equal to 95 ohms per kilometer, helping support consistent transmission across supported network distances.
24AWG Cable Construction
The cable uses 24AWG conductors arranged as four twisted pairs. Each pair is color coded according to standard network wiring conventions, helping installers identify and terminate pairs correctly during installation.
The pairs include blue, green, orange, and brown combinations with corresponding white-striped conductors.
This standard color arrangement makes the cable suitable for commonly used Ethernet termination methods such as T568A and T568B when installed with compatible connectors and patch panels.
Fluke Tested up to 90 Meters
Uniview specifies Fluke testing for network runs up to 90 meters. This provides additional confidence for professional network installations where performance verification is important.
Fluke testing is commonly used in structured cabling projects to confirm that installed network cables meet expected transmission requirements.
This makes the CAB-LC3100B-E2-IN suitable for businesses and installers who need dependable network cable for permanent infrastructure.
Durable PVC Outer Sheath
The cable uses a PVC outer jacket designed to protect the internal twisted pairs during handling and installation.
Uniview specifies an external diameter of approximately 5.6 ±0.3 mm and a sheath thickness of approximately 0.55 ±0.1 mm.
The durable outer jacket helps protect the internal conductors while allowing the cable to remain flexible enough for routing through cable trays, conduits, network cabinets, and structured cabling pathways.
Orange Jacket for Easy Identification
The bright orange outer jacket makes the cable easy to identify in racks, cable trays, ceiling spaces, and structured cabling environments.
Color-coded cabling can be useful in larger network projects because it allows installers and IT teams to separate different network functions or identify specific cable runs more quickly.
The printed outer surface also helps with cable identification and measurement during installation.
HDPE Insulation
The internal conductors use HDPE insulation, which helps electrically isolate the twisted pairs and supports stable signal transmission.
Each insulated conductor has a nominal diameter of approximately 0.90 ±0.05 mm according to Uniview specifications.
The combination of copper conductors and HDPE insulation provides a practical construction for professional Category 6 network installations.
Integrated Separator and Rip Cord
The CAB-LC3100B-E2-IN includes an internal separator designed to help maintain pair separation and improve cable performance.
A rip cord is also included, making it easier for installers to remove the outer jacket during cable preparation and termination.
These installation-focused features help make the cable more convenient for professional cabling technicians working with larger projects.
Wide Operating Temperature Range
Uniview specifies an ambient operating temperature range from approximately -20°C to 75°C.
This wide temperature tolerance allows the cable to be used in many controlled indoor networking environments and technical installations.
Correct installation practices and suitable environmental conditions remain important to ensure long-term network performance.
Ideal for CCTV and IP Camera Networks
This cable is particularly suitable for IP surveillance systems where cameras, network switches, NVRs, and other devices need reliable Ethernet connectivity.
A 305-meter roll can support multiple camera runs across offices, warehouses, retail stores, commercial buildings, and other surveillance environments.
When used with compatible network infrastructure, the cable can help provide stable communication between IP devices throughout the installation.
Suitable for Offices and Enterprise Networks
The Uniview CAB-LC3100B-E2-IN can also be used for structured office networks, server rooms, access points, VoIP phones, desktop computers, printers, and network switches.
Its solid copper construction and Category 6 design make it a practical choice for businesses that need reliable network cabling across multiple workstations and network devices.
For more networking products, switches, CCTV equipment, cables, and enterprise technology solutions, visit
Smart Land Technology.
For complete technical specifications and official product information, visit the
official Uniview CAB-LC3100B-E2-IN product page.
Why Choose Uniview CAB-LC3100B-E2-IN?
The Uniview CAB-LC3100B-E2-IN combines solid bare copper conductors, Category 6 UTP construction, a 305-meter packing length, and a durable PVC jacket in one professional networking solution.
Its 24AWG conductor design, internal separator, rip cord, HDPE insulation, and Fluke-tested performance make it suitable for installers who need dependable cable for structured network projects.
Overall, the Uniview CAB-LC3100B-E2-IN is a reliable Cat6 Cable for professional networking, CCTV, office, and enterprise installations. Its 305-meter length, solid copper construction, orange PVC jacket, and proven network performance make it a strong choice for modern structured cabling projects.

Reviews
Clear filtersThere are no reviews yet.